Permit/Application Details
Information for Permit #: 24 101476 TJ
| Project Name: | Comcast 776397 2009 121st Ave SE |
|---|---|
| Jurisdiction: | BELLEVUE |
| Type: | TJ |
| Address: | 2009 121st Ave SE |
| Parcel: | 9542200080 |
| Status: | Closed |
|---|---|
| Applied Date: | 1/17/2024 |
| Application Expiration: | |
| Issued Date: | 1/22/2024 |
| Finaled Date: | 12/27/2024 |
| Permit Expiration: | 1/19/2025 |
Description
ext 8/13/24 kb. Underground horizontal directional boring using surface launched drill to install 2" Comcast conduit to 2009. Starting at flushmount ped located on S side of 1849's driveway, crew will bore S/SW approx 121' to a placed handhole on S side of 2009's driveway and W approx 2' to 2009's property line. Route will finish on private property W/SW approx 41' to 2009's connection. Potholing on soft surface is needed, max pothole dimension 2' x 2'. 2' of vertical seperation will be kept between bore path and storm main/sewer lateral line. 6' of horizontal seperation will be kept between bore path and paralleling sewer main.
See Permit or Approved Plans for Conditions