Closed. Applicant needs to reapply per inspection. MD*
ext 8/2/24 kb. EXT 1/18/24 KB. EXT 8/22/23 KB. EXT 1/20/23 KB. BORE 2" CONDUIT UNDERGROUND FOR COMCAST FROM METER BOX LOCATED ON N SIDE OF 4679, E TO EXISTING CARSON THEN NE ALONG 174TH CT SE TO PED LOCATED NEAR PROPERTY LINE OF 4675 AND 4671. BORE PATH TO CROSS OVER EXISTING UNDERGOUND WATER AND SEWER LATERAL LINES. MAINTAINING THE APPROPRIATE CLEARANCE FOR ALL UTILITIES, 5' HORIZONTAL CLEARANCE FROM UTILITY APPURTENANCES AND 2' VERTICAL CLEARANCE FROM ALL SUBSTRUCTURES. ALL NEW SUBSTRUCTURE TO HAVE 36" COVER. POTHOLING ALL UNDERGROUND UTILITIES PER CITY INSPECTOR'S REQUEST. BORE PIT SIZES : 6" WIDE, 3' LONG, 3' DEEP. BORE PIT LOCATIONS : NEXT TO EXISTING CARSON LOCATED NEAR PROPERTY LINE OF 4679 AND NEAR COMCAST PED LOCATED NEAR PROPERTY LINE OF 4675 AND 4671.